St Aloysius Catholic College, nestled in the picturesque Kingborough Municipality just south of Hobart, Tasmania, stands as a beacon of education as a co-educational Catholic institution. Recently, the college embarked on an exciting expansion project by opening a brand-new Senior Campus (Years 9-12) in Huntingfield. This move was driven by the rapidly growing student population in the region, ensuring that more young minds have access to quality education. At Westlab, our commitment to being a trusted partner in science education led us to collaborate with St Aloysius College. Our goal was to provide a holistic 360° solution for equipping and organizing their state-of-the-art laboratories. As one of our core missions is to support educational institutions like St Aloysius, we took pride in delivering a tailored approach that addressed their specific requirements. Setting up a laboratory, whether new or renovated, is no small feat. It demands a wide array of products and services that align with the school’s unique needs. Westlab worked hand-in-hand with St Aloysius College to fully grasp their vision and objectives. Based on this collaboration, we crafted a customized solution that encompassed a curated selection of high-quality products: - **Lab Consumables**: From essential glassware and plasticware to a comprehensive range of chemicals. - **Benchtop Equipment**: A versatile lineup of equipment to support diverse scientific experiments, including microscopes, hotplates, balances, and bottle top dispensers. - **Temperature-Controlled Storage Solutions**: Fridges and freezers designed to preserve sensitive materials and samples. - **General Storage Solutions**: Practical Gratnells Trolleys to maintain organization and efficiency within the lab space. - **Labware**: A variety of labware to optimize functionality and streamline workflows. - **Water Filtration & Deionizer Systems**: Ensuring access to pure water for all laboratory applications. Our partnership with St Aloysius College is a testament to Westlab's dedication to supporting educational institutions and fostering a passion for science among students. By providing a seamless blend of products and services, we helped create an environment where curiosity and learning can thrive. This project not only highlights our ability to deliver tailored solutions but also underscores our commitment to empowering educators and students alike. Together, we’re shaping the future of science education, one lab at a time.

Centrifuge Tube

Centrifugal tubes are generally disposable experimental devices and are not recommended for repeated use. In order to save money, PP centrifugal tube can be reused according to the situation, but it needs to be thoroughly disinfected by high temperature and high pressure to ensure the scientific results of the experiment. PE material centrifugal tube, can not be high temperature and high pressure disinfection.

We all know that in plastic centrifugal tubes, commonly used materials are polyethylene (PE), polycarbonate (PC), polypropylene (PP) and so on. The performance of polypropylene PP tube will be relatively good. Therefore, we should consider the plastic centrifugal tube of polypropylene as far as possible when selecting plastic centrifugal tube.


Use method of centrifugal tube:
1. Because the graduated centrifugal tube is a metering device, it must be cleaned and dried before use.
2. When reading, be sure to observe the bending liquid level correctly, otherwise it will introduce a certain error.
3. When used, the number of centrifugal tubes should be determined according to the model of the centrifuge. For example, if a centrifuge with two tubes is used for a single test, the same volume of liquid must be loaded into the other centrifugal tube to maintain balance.
4. The centrifuge tube and the centrifuge casing should be compatible. Pipe should not be too long, otherwise it is easy to break when rotating. But it is not easy to be too short, too short pipe is unstable when rotating in the air, and easy to cause breakage. Too thick sleeve not into, too thin rotation instability, round mouth should be greater than the inner diameter of the casing.
5. After the centrifugal tube is placed into the casing of the centrifuge for stratified separation, it should be stopped naturally when it stops rotating, and it should never be forced to stop by external force.

Precautions for centrifugal tube:
When we use centrifugal tube, do not use a tube many times, pay attention to the sample volatilization and some radioactive or corrosive sample leakage; In the storage process, it is necessary to seal well; It is necessary to prevent the deformation of centrifugal tube in the process of use.