Backwash filter installation method and precautions for use

Backwashing filter is a kind of filter that directly intercepts impurities in water, removes suspended solids and particulate matter, reduces turbidity, purifies water quality, reduces system fouling, bacteria, rust, etc., to purify water and protect other systems. Precision equipment for normal work. The water enters the self-cleaning filter body from the water inlet. Due to the intelligent (PLC, PAC) design, the system can automatically identify the degree of impurity deposition and automatically discharge the sewage valve signal.

1. Installation only needs to be connected to the pipeline according to the direction of the water in the direction of the arrow on the equipment cylinder;

2. When designing and installing, try to consider the sewage outlet at the lower part to facilitate the smooth discharge of debris;

3. The sewage pipe should be connected to the drainage ditch near it, and the sewage should be kept smooth;

4. In order to facilitate observation of system operating conditions and daily operations, pressure gauges and manual valves should be installed at the inlet and outlet;

5, when discharging sewage, according to the sewage situation, through the switch valve, the filter is washed for 10-20 seconds;

6, the use of the microcomputer controller:

(1) Setting method of outlet pressure value: After the system is running, observe the inlet water pressure value of the equipment, and then adjust the value of the outlet water pressure gauge to be less than the inlet water pressure value of 0.06-0.08 MPa. For example, the inlet water pressure is 0.4 MPa. Then, the value of the water and electricity contact pressure gauge can be adjusted to be between 0.32 and 0.34 MPa.

(2) Then turn on the microcomputer and turn on the power switch on the control panel.

(3) If the outlet pressure is lower than the set pressure value at this time, the device remains in the working state, the work indicator light is on, the automatic actuator opens the valve plate, and the drain solenoid valve (or electric valve) is closed.

(4) If the outlet pressure is lower than the set pressure value, the device enters the backwash state, the backwash indicator lights, the automatic actuator closes the valve plate, and the drain solenoid valve (or motor valve) opens. After the backwashing process is delayed for 2-4 minutes, it returns to the working state. If the outlet pressure is higher than the set pressure value at this time, the equipment maintains the normal water discharge state; if the outlet water pressure is still lower than the set pressure value, the equipment works for 2-4 minutes, backwashing for 2-4 minutes, and so on, until repeated The outlet pressure value is higher than the set pressure value.

(5) Backwashing The ram shaft and the equipment cylinder are double rubber ring seals (or PTFE filler). If water leakage occurs during use, use a small wrench to tighten the three screws on the gland properly and evenly. Circle, subject to no water leakage. If the gland is pressed to the bottom and the water leakage cannot be solved, a new seal or packing needs to be replaced (the seal size model is based on the random spare model).

The above contents are compiled according to the problems encountered by the students in the actual work, for reference, if there is any problem, please communicate and correct in time.

When the operating parameters of the equipment can not meet the requirements of the user, the user can set various parameters according to the actual working conditions, and select manual control and automatic control mode to work.

When running for the first time, follow these steps:

Check if the filter is working properly:

Check to see if the connections at the filter are secure.

Look at the filter electrical control box section should be dry.

When the power is turned on, the green power indicator is on. At this point, the electronic control part of the filter is in normal working condition, and the device can be put into trial operation.

Note: Pay attention to keep the hand dry when plugging in the power supply. At the same time, keep the electronic controller part dry during the working process of the filter, and no water can enter the inside of the electric controller.

The above contents are compiled according to the problems encountered by the students in the actual work, for reference, if there is any problem, please communicate and correct in time.