Lufthansa News (7): How to choose the right oxygen electrode (Clark electrode)

Lufthansa Newsletter (7)
How to choose the right oxygen electrode (Clark electrode)
Lufthansa Scientific Instrument Co., Ltd. (Shandong 271000)
(for more information, please visit Lufthansa website)
Phone: 0538-8241341/8249608 Fax
     At present, the most widely used and most authoritative oxygen electrode (Clark electrode) in the world mainly includes Oxytherm, Oxygraph, Chlorolab-2, Chlorolab-3, Oxyview, Leaflab-2 and other oxygen electrodes (Hansatech, UK). The function of the oxygen electrode is similar and slightly different. How can I choose the oxygen electrode that is suitable for my experiment? First we need to understand the function of various types of oxygen electrodes.
The main purpose of the oxygen electrode:
The British Hansatech oxygen electrode is a high precision Clark oxygen electrode for the determination of dissolved oxygen in aqueous solutions. It is often used to study the photosynthetic rate of various animal, plant, microbial tissue respiration rate, plants, algae, etc. It is also used to study the changes of respiratory rate and respiratory pathway of plant tissues such as plant roots, buds, seeds, fruits, leaves and other tissues. The changes of cyanide-resistant respiratory pathway, cytochrome oxidase pathway, glycolysis pathway and tricarboxylic acid pathway were analyzed, and then the changes of plant stress resistance, tissue dormancy and dormancy release were analyzed.
Study mitochondrial respiration, I state, II state, III state, IV state respiration, and respiratory control rate, P / O ratio.
With powerful WINDOWS software, the data is recorded and analyzed by the computer, and the breathing rate is automatically calculated.
The difference between each oxygen electrode:
Among the most popular oxygen electrodes sold above, Chlorolab-2 and Chlorolab-3 oxygen electrodes (with light source) can perform all of the above measurements.
The Oxygraph and Oxytherm oxygen electrodes are not compatible with the Chlorolab-2/3 type because they do not have a light source and cannot measure the photosynthetic rate. Therefore, the main difference between Chlorolab-2/3 and Oxytherm/graph is that the former can measure photosynthesis, and the latter cannot.
The main difference between Oxytherm and Oxygraph oxygen electrodes is that Oxytherm has temperature control equipment, which can automatically control temperature. The temperature control accuracy is 0.02 °C, and the temperature control range is 3-40 °C. The other features are the same.
Oxygraph can be used to control the temperature in a circulating water bath, but an additional water bath is required (the one must have circulating water)
The main difference between the Chlorolab-2 and Chlorolab-3 types is that the maximum capacity of the Chlorolab-2 type reaction cup is 5 ml and the maximum capacity of the Chlorolab-3 type reaction cup is 20 ml, the others are the same.
pay attention:
The Chlorolab-2/3 oxygen electrode is equipped with a red light source (suitable for the determination of higher plants), so when measuring algae, an additional white light source is required (not the main absorption zone of algae is not in the red zone, Some algae have obvious absorption peaks in the blue-violet region, and a single red light source cannot meet the needs of photosynthesis.
Red light source: Maximum light intensity 1200umol m-2 s-1, computer accurately controls light intensity, suitable for photosynthesis of higher plants.
White light source: maximum light intensity 1800umol m-2 s-1, maximum light intensity up to 8000umol m-2 s-1 after concentrating components and optical fiber, filter control light intensity, suitable for lower plants (such as algae, etc.) ) photosynthesis with higher plants.
Oxygen electrodes are widely used in many fields such as plant physiology, agronomy, horticulture, pathology, food college, microbiology, zoology, biochemistry, analytical chemistry, sports and health.
Main application units: schools, hospitals, research institutes
Institute of Botany, Institute of Genetics, Nutrition Institute, Institute of Microbiology, Institute of Energy, Aquatic Institute, Union Hospital, Xiangya School of Medicine (Northern Union and Nanxiangya), Tsinghua University, Peking University, Zhejiang University, China Agricultural University, Fudan University, Nankai, Shangda, Sun Yat-sen University, Jinan University, Lanzhou, Nanda, Wuda and so on.

Flame Retardant Reflective Fabric


Reflective warning`s reflection part of the garments is the use of lattice micro-rhombus type refraction and high refractive index of glass beads back to the principle of reflection, through the post-processing of advanced processing technology made. It can reflect the distant light back to the light. Both in the day or night have a good retroreflective optical performance. Especially at night, it can play the same high visibility as the day. The use of this high-energy reflective material made of safety clothing, whether the wearer is in the distance, or in the light or scattered light interference, it can be relatively easy to be found by the night driver.